Chapter 6
Service and Maintenance
Alarm
Set Message
Shutdown
WDOG task:
Event
watchdog
Secondary WD has
expired
System
System Startup
Startup
LMI Setup
LMI SDRAM
exhaust test failed
Param
DB NVS flushing
Storage
ignored
Param
RAM flush to NVS
Storage
failed
Param
DB Factory Reset
Storage
failed
Flash
RECORD: init
Storage
failed
Flash
RECORD
Storage
MANAGER:
Record contents
check error,
erasing all
Flash
RECORD: sector
Storage
setup check error,
erasing sector
LNB PS
LNBPS: No Load
LNB PS
LNBPS: Over
Temperature
OL-31085-01
Cause
Remedy
The software detected
Clear alarms, reset the
an error in operation.
unit, and notify Cisco
customer support if the
problem persists.
Restarted the D9865
None. It will
Satellite Receiver.
automatically reset after
1 second.
DDR RAM on LMI bus
Clear alarms, reset the
not working due to a
unit, and notify Cisco
hardware issue.
customer support if the
problem persists.
Non-volatile storage
Clear alarms, reset the
system failed to fully
unit, and notify Cisco
update due to a
customer support if the
hardware issue.
problem persists.
Non-volatile storage
Clear alarms, reset the
system failed to fully
unit, and notify Cisco
update due to a
customer support if the
hardware issue.
problem persists.
Non-volatile storage
Clear alarms, reset the
system failed during
unit, and notify Cisco
factory reset.
customer support if the
problem persists.
Non-volatile storage
Clear alarms, reset the
system corrupted due to
unit, and notify Cisco
a hardware issue. There
customer support if the
is a possible loss of
problem persists.
configuration.
NVS corruption and
Clear alarms, reset the
loss of configuration
unit, and notify Cisco
data due to a hardware
customer support if the
issue.
problem persists.
NVS Corruption and
Clear alarms, reset the
loss of sector data due to
unit, and notify Cisco
a hardware issue.
customer support if the
problem persists.
LNB power overload
Clear alarms, check
due to a hardware or
LNB and wiring. Notify
wiring issue.
Cisco customer support
if the problem persists.
LNB power overload
Clear alarms, check
due to a hardware or
LNB and wiring. Notify
wiring issue.
Cisco customer support
if the problem persists.
Cisco D9865 Satellite Receiver Software Version 2.20 Installation and Configuration Guide
Alarm Messages
Severity
Clear Message
Major
None.
Minor
Backup/Restore System
Startup.
Major
LMI Video SDRAM
exhaust test passed
Major
DB flushing completed
Major
DB flushing completed
Major
DB Factory Reset
completed
Major
RECORD: init done
Major
Major
Minor
LNBPS: Normal
Minor
LNBPS: Disabled
6-7