2 Installation and Commissioning, IRC5

2.4.1. Required installation space, IRC5 Controller

2.4 On-site Installation

2.4.1. Required installation space, IRC5 Controller
Dimensions
The figure below shows the required installation space for the IRC5 controller, the illustration
shows a Single Cabinet Controller. The measures are the same for the Dual Cabinet
Controller.
xx0500001848
NOTE! The free space on the right hand side of the controller is required to allow opening
the door a full 180° and to access the optional moist dust filter.
NOTE! The air distance 300 mm on the backside of the controller is required to allow
inspection and replacement of the optional moist dust filter and ensure proper cooling.
NOTE! Do not place customer cables over the moist dust filters on the backside of the
controller. Makes difficult to inspect and replace the moist dust filters.
42
3HAC021313-001 Revision: P