4 Repair activities, controller IRC5

4.29.5. Replacement of drive system power supply

4.29.5. Replacement of drive system power supply
Location
The illustration below shows the location of the drive system power supply in a Single
Cabinet Controller.
In the Dual Cabinet Controller the drive system power supply is located in the Drive Module.
xx0500001951
A
B
C
D
E
F
Required equipment
Equipment
Drive system power supply 3HAC026289-001
Drive system power supply 3HAC020466-001
Standard toolkit
Other tools and procedures
may be required. See
references to these
procedures in the step-by-
step instructions below.
Circuit Diagram
284
Contactor interface board
Contactor
Drive system power supply
Customer I/O power supply
Control power supply
Backup energy bank
Spare part no.
Art. no.
Note
DSQC 626A
DSQC 627
The contents are
defined in section
Standard toolkit!
These procedures
include references
to the tools
required.
3HAC024480-004
Complete control
system
Continues on next page
3HAC021313-001 Revision: P