Samsung DCS Programming Manual page 74

Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG DCS
TECHNICAL MANUAL
MMC: 311
PARAMETER
DESCRIPTION:
Assigns and sets parameters for the serial interface module (SIM).
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
HOLD
ACTION
1.
Press TRSF 311
Display shows
2.
Enter station number of SIM (e.g., 257) from dial key pad
OR
Press UP or DOWN key to make selection and press
RIGHT soft key to move cursor
3a.
Enter in desired selection from table "A" (e.g., 01)
OR
Press UP or DOWN key to make selection
And press RIGHT soft key to move cursor
3b.
Enter in desired selection from table "B" (e.g., 02)
OR
Press UP or DOWN key to make selection and press
RIGHT soft key to move cursor to step 4
3c.
Enter in desired selection from table "D" (e.g., 02)
OR
Press UP or DOWN key to make selection and press
RIGHT soft key to move cursor to step 4
3d.
Enter in desired selection from table "E" (e.g., 03)
OR
Press UP or DOWN key to make selection
And press RIGHT soft key to move cursor to
step 4
ASSIGN SIM
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
Used to clear previous entry
PROGRAMMING
December 1996
DISPLAY
[256] SIM PARA.
SIM TYPE :DTE
[257] SIM PARA.
SIM TYPE :DTE
[257] SIM PARA.
CALL MODE:MANUAL
[257] SIM PARA.
SIM TYPE :DTE
[257] SIM PARA.
ANS MODE :MANUAL
[257] SIM PARA.
AUTO BAUD:ON