DESCRIPTION:
Provides the ability to customize the tone cadence on a system-wide basis. There are ten tone
cadences available. The tone control of the cadence may be changed from interrupt tone to
continuous tone. Some DCS systems may require default settings to comply with local operating
companies.
FEATURE KEYS
OPTIONS KEY
0
CONTINUOUS TONE
1
INTERRUPT TONE
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
TONES
BUSY TONE ERROR TONE
CONFM/BARGE
DIAL TONE
ACTION
1.
Press TRSF 506
Display shows
2.
Press UP or DOWN key to select tone
Press LEFT soft key and advance to step 3
3.
Press UP or DOWN key to select tone control
Press RIGHT soft key to advance to step 4
OR
Press LEFT soft key to return to step 2
4.
Dial in new value for interrupt times (must be four digits)
Press RIGHT soft key advances cursor
Press LEFT soft key retreats cursor back
If valid entry, system returns to step 2
5.
Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
RGBACK TONE DND/NO MORE
DID RNGBACK
HOLD/CAMPON
TONE CADENCE
RING TONE
TRSFER TONE
DISPLAY
BUSY TONE
CONTINUOUS TONE
TRSFER TONE
INTERRUPT TONE
TRSFER TONE
INTERRUPT TONE
TRSFER TONE:0100
0100 0100 0100
PROGRAMMING
December 1996
MSGWAT TONE