TECHNICAL MANUAL
MMC: 701
DESCRIPTION:
Similar to MMC 700 but does not allow a copy command. This MMC is primarily used for the
creation of a new class of service. If the feature of unsupervised conference is allowed, a
programmed CONF key must be available to allow reentry into conference call.
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
TOLL LEVEL OPTIONS
DIAL DIGIT
0
1
2
3
4
5
6
7
ACTION
1.
Press TRSF 701
Display shows
2.
Dial in COS (e.g., 06)
OR
Press UP or DOWN key to select COS and press RIGHT
soft key to move cursor to toll level
3.
Dial toll level (e.g., 2—see above list)
OR
Press UP or DOWN key to select new level of TOLL
OR
Press RIGHT soft key to advance to COS options
4.
Dial in COS option (e.g., 09—see option list)
OR
Press UP or DOWN key to select option and press RIGHT
soft key to move cursor
ASSIGN COS CONTENTS
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
TOLL LEVEL
A
B
C
D
E
F
G
H
PROGRAMMING
December 1996
DISPLAY
COS CONTENTS(01)
TOLL LEVEL:A
COS CONTENTS(06)
TOLL LEVEL:A
COS CONTENTS(06)
TOLL LEVEL:C
COS CONTENTS(06)
09:DND
:YES