Samsung DCS Programming Manual page 135

Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG DCS
TECHNICAL MANUAL
MMC: 510
DESCRIPTION:
Provides the ability to customize the Message Wait LED cadence. There are two cadences
available. The two cadence are CONTINUOUS & INTERRUPT. The LED cadence control may be
changed from interrupt to continuous. The default setting of interrupt cadence is from 2000 to
2000.
The two options are as follows ;
• CONTINUOUS
• INTERRUPT
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
HOLD
ACTION
1.
Press TRSF 510
2.
Press UP or DOWN key to select cadence or
Press digit 0 or 1 via Dial Key Pad
3.
If you select the INTERRUPT LED mode, You can enter
the new value using keypad (default value is 2000)
4.
Press TRSF button to store and exit
Press SPK button to store and advance to next MMC
DEFAULT DATA:
RELATED ITEMS: NONE
MESSAGE WAIT LED CADENCE
: When the Message is accepted to the SLT that has Message Wait LED,
the Message wait LED will be turned on continuously.
: On the above state, the LED will be filckered. The flickering interval can
be set/changed by MMC.
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
Used to clear previous entry
OR
NONE
PROGRAMMING
DISPLAY
MW LED CADENCE
CONTINUOUS LED
MW LED CADENCE
INTERRUPT LED
MW LED CADENCE
2000 2000
JUNE 1997

Advertisement

Table of Contents
loading

Table of Contents