DISA DISCONNECT: This timer controls the maximum duration of a DISA call.
This timer controls the duration of time a DISA call is not allowed to
DISA LOCK OUT TIMER:
be made after the DISA error counter has expired (MMC 500).
DISA PASS CHECK: This timer defines the time period before the system clears the incorrect
passcode counter.
DISPLAY DELAY TIMER: This timer controls the duration a display is shown in the LCD display. This
timer also controls the duration of time that error tone is heard.
DOOR LOCK RELEASE: This timer controls the duration of time the door lock relay will be activated.
DOOR RING DETECT: This timer controls the duration of time before a call is answered by the door
phone.
DOOR RING OFF TM: This timer controls the duration of ringing at the door ring destination before
automatically canceling.
E-HOLD RECALL TM: This timer controls the duration of time a call is held exclusively at a station
before recalling.
EXT. FWD DELAY TM: This timer controls the External Call Forward feature which will allow a station
to ring before the call is placed on external call forwarding.
FIRST DIGIT TIME: This timer controls how long the system will wait for dialing to begin before
dropping the dial tone and returning the user to error tone.
HOK FLASH MAX TM: This timer monitors the duration of a hookswitch flash to ensure that the flash
is valid and not a line noise or an accidental hookswitch bounce (LONGEST DURATION).
HOK FLASH MIN TM: This timer monitors the duration of a hookswitch flash to ensure that the flash
is valid and not a line noise or an accidental hookswitch bounce (SHORTEST DURATION).
HOOK OFF TIME: This timer controls the time before dial tone is sent to a single line station.
HOOK ON TIME: This timer sets the minimum amount of time that the system will recognize as an
SLT hang up.
INQUIRY RELEASE: This timer monitors the duration of the interaction of the soft key to determine
when to return the LCD back to a normal status. This timer affects only display phones.
INTER DIGIT TIME: This timer controls the grace period between dialing valid digits before dropping
the call and returning the user back to error tone.
KMMC DIGIT TIME: This timer controls the grace period between programming actions while in a
programming session. The timer automatically returns the system to secure programming status.
LCR ADVANCE TIME: This timer controls the duration of time before selecting the next allowable
route when a station is allowed to route advance.
LCR INTER DIGIT: This timer controls the grace period between dialing valid digits before dropping
the call and returning the user back to error tone.
MCL DELAY TIME: This timer controls the time when the system should start transmitting
Authorisation code after sending MCL Access code.