CHAPTER 2. MMC Programming
No
Code
MNF--
64
MNF01
65
MNF02
66
MNF03
67
MNF04
68
MNF05
69
MNF06
70
MNF07
71
MNF08
72
MNF09
73
MNF10
74
MNF11
75
MNF12
76
MNF13
77
MNF14
78
MNF15
79
MNF16
Samsung Business Communications
Alarm Name
Minor Error
Minor Fault with Alarm Buffer saving
Card Out
A circuit card mounted in a universal slot has been re-
moved from service or is not recognized by the system
Alarm Data = Cabinet, Slot (Cx-Syy)
Card In
A circuit card mounted in a universal slot has been re-
turned to service.
Alarm Data = Cabinet, Slot (Cx-Syy)
IPC Error
Inter-processor communication error has occurred.
Alarm Data = Cabinet-Slot (Cx-Syy)
Trunk Fault
Out of service trunk detected via loop detect. Internal
CODEC test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Trunk Recovery
Out of service trunk detected via loop detected as out of
service is now operational.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Trunk Discon-
Out of service trunk detected via seizure of trunk. Exter-
nect
nal seizure test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Trunk Connect
Out of service trunk recovered via seizure of trunk. Ex-
ternal seizure test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
SIO TxQ Over
SIO Tx Queue full error has occurred in the MCP2.
Alarm Data = SIO number (SIO: x)
SIO TxQ Under
SIO Tx Queue under error has occurred in the MCP2.
Alarm Data = SIO number (SIO: x)
E1 Out Of Srv
E1 Digital line status has been changed to out of ser-
vice.
Alarm Data = Cabinet, Slot (Cx-Syy)
E1 In Service
E1 Digital line has been restored to normal service.
Alarm Data = Cabinet, Slot (Cx-Syy)
SIO Out
IO port has lost DTR
Alarm Data = SIO number (SIO: x)
SIO In
IO port has regained DTR.
Alarm Data = SIO 1 through 6
TODC Error
Time of Day Clock in the MCP2 has erred.
TSW Over Alarm
The TSW has been requested to exceed the capacity of
available time slots. Maximum 192 per cabinet.
Alarm Data = Cabinet, Slot (Cx-Syy)
PSU Alarm
There are more ports than can be supported in a
cabinet and more power is required.
Alarm Data = Cabinet, Slot (Cx-Syy)