CHAPTER 2. MMC Programming
No
Code
MJD--
33
MJD01
34
MJD02
35
MJD03
36
MJD04
37
MJD05
38
MJD06
39
MJD07
40
MJD08
41
MJD09
42
MJD10
43
MJD11
44
MJD12
45
MJD13
46
MJD14
47
MJD15
48
MJD16
49
MJD17
Samsung Business Communications
Alarm Name
DTRK Error
ISDN or E1 card Fault
Sync Failure
Clocking on TEPRI cards has become asynchronous.
Sync Recovery
Clocking on TEPRI cards has become synchronous.
Red Alarm
Locally detected loss of PCM carrier on TEPRI card for
more than 250 ms.
Alarm Data = Cabinet, Slot (Cx-Syy)
Red Alarm Rec
PCM carrier detected locally on TEPRI cards.
Alarm Data = Cabinet, Slot (Cx-Syy)
Yellow Alarm
Remotely detected failure transmitted in frame on
TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
Yellow Alarm
Remotely detected failure restored transmitted on
Rec
TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
Blue Alarm
All 1's being transmitted on facility on TEPRI card.
Alarm Data = Cabinet, Slot (Cx-Syy)
Blue Alarm Rec
A blue alarm condition has been cleared.
Alarm Data = Cabinet, Slot (Cx-Syy)
Bit Error Alarm
Alarm is activated when the error rate exceeds 1x10
rors. Note: 1x10
threshold for major alarm errors on E1, PRI or BRI.
Alarm Data = Cabinet, Slot (Cx-Syy)
NTWRK Event
An Implausible event has occurred on the PRI or BRI
Network digital line. Protocols do not match or sub-
scriber ID mismatch.
Alarm Data = Cabinet, Slot (Cx-Syy)
SPID Init Error
The BRI received an error from the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
SPID Init Rec
The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
LPBK Error
Internal on demand loopback failed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
LPBK Recovery
Internal on demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
BRI DL Unavail
A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
BRI DL Recovery
A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
RAM Error
An error has occurred in the TEPRI or BRI card RAM.
Alarm Data = Cabinet, Slot (Cx-Syy)