Samsung OfficeServ 7200 Programming Manual page 361

Enterprise ip solutions
Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

CHAPTER 2. MMC Programming
No
Option
04
CTI LINK OPTION
05
ITP DSP PARA
06
ITP TX GAIN/HSET
07
ITP RX GAIN/HSET
Samsung Business Communications
Description
Sets CTI link via LAN option with the system.
0 SMDR REPORT: Sets YES or NO for SMDR data
to CTI link via LAN.
1 UCD REPORT: Sets YES or NO for UCD data to
CTI link via LAN.
2 ALIVE: This is a CTI link via LAN alive check
timer. If this is set to 0, the system will not
check link alive.
Sets IP phone DSP parameter system wide.
0 M-FRAME: This value determines the trans-
mission interval time of VoIP packets generated
by the IP phone. This data uses DOWN = SYS
DATA only (see 3, below). The range is
10~40 ms.
1 JITTER: Decides the minimum time to consider
delay for jitter adjustment. This data uses
DOWN = SYS DATA only (see 3, below). The
range is 10~90 ms.
2 TOS: An 8-bit binary value that will be used by
external routers, switches, etc, (that optionally
support TOS-bit prioritization) to identify the
transport-priority value of data packets gener-
ated by the IP phone. This value can be left at
the default value (00000) if your network infra-
structure does not support this method of
bandwidth management. This data uses DOWN
= SYSTEM DATA only (see 3, below).
3 DOWN: Determines whether system-wide data
or individual phone data is used for DSP control
of IP-based phones.
a) SYSTEM DATA: System-wide data will be
used (MMC 841)
b) PHONE DATA: Individual phone data will
be used (MMC 840)
Sets IP-based phone Handset TX gain value of
each level.
Sets IP-based phone Handset RX gain value of
each level.
OfficServ 7200 Programming Guide
Default
NO
NO
300 SEC
10 ms
20 ms
All bits 0
SYS DATA
Depends on
country
Depends on
country
2-330

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents