CHAPTER 2. MMC Programming
[504] PULSE MAKE/BREAK RATIO
Allows the ability to change the value of pulses per second and the duration of the
make/break time. This will only affect rotary dial trunks.
No
0
MAKE/BREAK RATIO
1
PULSE PER SECOND
DEFAULT DATA
MAKE/BREAK: 33 MAKE
PULSES PER SECOND: 10 PPS
ACTION
1. Press Transfer button and enter 504.
Display shows:
2. Dial 0 or 1 for option.
OR
Press Volume button for selection and press
Right Soft button to move cursor.
3. Dial new value.
System returns to step 2.
4. Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
MMC 402
Samsung Business Communications
Item
Make/Break ratio of dial pulse (01-99)
Number of dial pulses per second (10 or 20)
TRUNK DIAL TYPE
OfficServ 7200 Programming Guide
Description
DISPLAY
MAKE/BREAK RATIO
33 MAKE
PULSE PER SECOND
10 PPS
_
PULSE PER SECOND
10 PPS
20
2-151