CHAPTER 2. MMC Programming
[852] SYSTEM ALARM ASSIGNMENTS
This MMC allows the assignment of system alarms to ring and display on stations that
have an Alarm key assigned. The Alarm key is assigned in MMC 722 (Station Key Pro-
gramming). Alarm key programming is tenant wide (tenants 1 and 2). Alarms not pro-
grammed to report to the system Alarm key will still be retained in the maintenance alarm
buffer for Alarm Reporting (MMC 851). The alarm buffer holds up to 100 alarms on a First
In-First Out (FIFO) basis. Pressing the Alarm key will silence the audible alarm until an-
other alarm is generated by the system. Alarm conditions that have multiple causes (e.g.,
PRI errors and synchronization loss) will print all associated alarm information if an SIO
port is programmed as an ALARM port. The specific fault alarm data can be displayed via
MMC 851, System Alarm Reporting.
Alarm Code Definitions:
No
Code
MJA--
01
MJA01
02
MJA02
03
MJA03
04
MJA04
05
MJA05
06
MJA06
Samsung Business Communications
Alarm Notification Off/On (0/1) determines if the alarm provides a visual and au-
dible notification to the system Alarm key station(s). Pressing the Alarm key and
the Release key will silence the audible alarm only at the station that pressed the
Alarm key and the Release key.
Alarm Name
MCP2 Error
POR Restart
Soft Restart
Mem Reset
MCP Reset
LCP Reset
PCM Switching
System Fault
MCP2 restart process has been executed via power on
restart (POR).
MCP2 restart process has been executed via button reset.
The system RAM has been cleared via manual program-
ming (PCMMC or KMMC) resulting in a system reset.
The MCP2 has software exception error.
Alarm data = Reason
- BUS ERR: Restart Bus Error
- ADDR.ERR: Restart Address Error
- ILLEGAL: Restart Illegal Opcode
- ZERO DIVID: Restart Zero Divide
- PRIVILEGE: Restart Privilege Violation
- ENDL LOOP: Restart Endless Loop
The SCP2 or LCP2 has reset
Alarm data = Cabinet (1, 2 or 3)
A fault has occurred in the Switching Control
Alarm data = MCP BASE, ESM: 1, ESM: 2 or ESM: 3
OfficServ 7200 Programming Guide
Definition
2-353