System Troubleshooting Tools

You can perform a number of manually-initiated tests from the Cisco WAN Manager NMS console to
assist in system troubleshooting. These tests may be included in a job so they can be scheduled to run
remotely at a specified time if desired.

User-initiated Tests

Several user-initiated tests can be used to diagnose system problems. These tests are self-contained in
that they do not require the use of external test equipment. They also do not require you to place a
loopback at the far end to test both directions of transmission. These tests are listed in Table 29-3.
Several display commands can be used to obtain information that may be helpful in troubleshooting
system problems. These are also listed in Table 29-3.

Table 29-3 System Troubleshooting Commands Available

Command
Test Connection (tstcon)—frame relay Performs a bi-directional test of the specified frame relay connection or range of
Test Connection (tstcon)—data
Test Connection (tstcon)—voice
Test Delay (tstdelay)—frame relay
Test Port (tstport)—frame relay
Test Port (tstport)—data
Display Connection States (dspconst)
Display Breakout Box
(dspbob)—frame relay
Display Breakout Box (dspbob)—data Same as above for synchronous data connections.
Display Breakout Box
(dspbob)—trunk
Display Buses (dspbuses)
Display Slot Errors (dspsloterrs)
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
1
Status
Downloading
Software
Minor
activated.
Description
connections by inserting a test pattern and comparing the returned pattern with the
pattern transmitted. A pass or fail indication appears next to the tested connection
in the Display Connections screen.
Same as above except for synchronous data connections.
Same as above except for voice connections.
Measures the round-trip delay over the selected frame relay connection.
Tests the operation of the selected frame relay port on the node.
Same as above except for synchronous data ports.
Displays in real-time the status of all voice connections terminating at a specified
node.
Displays in real-time the status of data and control leads on selected frame relay
connection.
Same as above for network subrate trunks.
Displays the status of system buses.
Displays any data errors associated with the slots in a BPX node.
Description
There are downloader commands that appear when the
system is down- loading software to the BCC.
BCC Redundancy alarm indicates node is configured for
redundancy but no standby BCC is equipped.