Cisco BPX-BXM-155-8DX Installation And Configuration Manual page 568

Cisco bpx-bxm-155-8dx: user guide
Table of Contents

Advertisement

Upgrade Options
Table A-2
Upgrade Options (continued)
Option
Used when...
Stand alone
Legacy BXM card is
BXM, manual
non-yred and the "auto
BXM upgrade"
parameter is set to "N"
for the cnfnodeparm
command.
Stand alone
Legacy BXM card is
BXM,
non-yred and the "auto
automatic
BXM upgrade"
parameter is set to 'Y'
for the cnfnodeparm
command.
Cisco BPX 8600 Series Installation and Configuration
A-4
Steps
Use an empty slot to configure the BXM-E card for the desired level of
1.
channel statistics and number of connections. The channel statistics level
and number of connections must be either equal to or higher than the ones
configured on the legacy BXM card that it is replacing. While this step is
optional, if skipped, the BXM-E card may not have the desired channel
statistics level and appropriate number of connections.
2.
Remove the BXM card and replace it with the BXM-E card. If step 1 is
skipped, the BXM-E card can create a mismatch if it does not have the
desired configuration. In that case, use the command cnfcdparm <BXM-E
slot_num> to set the card to the desired level of channel statistics and
number of connections. This may prolong service disruption.
Issue the upgdlogcd <log_card_num> command to upgrade the logical card
3.
database. Switch software upgrades the logical database from the number of
connections configured on the legacy BXM card to the number of
connections configured in step 1. From this point on, mismatch is declared
if the legacy card is reinserted.
Note
In non-yred cases, the traffic disruption is unavoidable
because the legacy BXM has to be removed and replaced
with the BXM-E card.
Use an empty slot to configure the BXM-E card for the desired level of
1.
channel statistics and number of connections. The channel statistics level
and number of connections must be either equal to or higher than the ones
configured on the legacy BXM card that it is replacing. While this step is
optional, if skipped, the BXM-E card may not have the desired channel
statistics level and appropriate number of connections.
2.
Remove the BXM card and replace it with the BXM-E card. If step 1 is
skipped, the BXM-E card can create a mismatch if it does not have the
desired configuration. In that case, use the command cnfcdparm <BXM-E
slot_num> to set the card to the desired level of channel statistics and
number of connections. This may prolong service disruption.
Switch software automatically upgrades the logical database when step 2 is
3.
done.
In non-yred cases, the traffic disruption is unavoidable
Note
because the legacy BXM has to be removed and replaced
with the BXM-E card.
Appendix A
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Upgrade Information

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents