Chapter 23
Configuring BXM Virtual Switch Interfaces

VSI Master and Slave Redundancy

The ability to have multiple VSI controllers is referred to as
enables multiple VSI masters to control the same partition.
You add a redundant controller by using the
(feeder) shelf, except that you specify a partition that is already in use by another controller. This
capability can be used by the controllers for cooperative or exclusive redundancy:
The switch software has no knowledge of the state of the controllers. The state of the controllers is
determined by the VSI entities. From the point of view of the BCC, there is no difference between
cooperative redundant controllers and exclusive redundant controllers.
For illustrations of a VSI Master and Slave, see to Figure 23-3. For an illustration of a switch with
redundant controllers that support master redundancy, see to Figure 23-8.
Switch software supports master redundancy in these ways:
The intercontroller communication channel is set up by the controllers. This could be an out-of-band
channel, or the controllers can use the controllers interface information advertised by the VSI slaves to
set up an intermaster channel through the switch.
Figure 23-8 below shows a switch with redundant controllers and the connectivity required to support
master redundancy.

Figure 23-8 Switch with Redundant Controllers to Support Master Redundancy

The controller application and Master VSI reside in an external VSI controller (MPLS or PNNI), such
as the Cisco 6400 or the MPLS controller in a 7200 or 7500 series router. The VSI slaves are resident
in BXM cards on the BPX node.
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Cooperative redundancy
Both controllers can be active in a partition, and can control the resources simultaneously.
Exclusive redundancy
Only one controller is active at a time. It is up to the controllers to resolve which should be active.
It allows you to add multiple controllers to control the same partition.
It sets up the control master-slave VCs between each of the controller ports and the slaves in the
node.
It provides controller information to the slaves. The slave advertises this information to the
controllers in the partition. The controllers can then use this information to set up an inter-master
channel.
VSI master redundancy.
command, the same way you add an interface
addshelf
Master-slave link
Inter-master link
Cisco BPX 8600 Series Installation and Configuration
VSI Master and Slave Redundancy
Master redundancy
Controlle
Controlle
23-19