M91 INVALID MEASUR. 9000
Details
Speed at contact is below minimum
The tool has contacted the sensor at the lower speed than set in "#1508 TLM_Fmin (Minimum speed
toward tool setter)".
Remedy
Correct the feed rate to move the tool to the sensor.
M91 INVALID MEASUR. 9001
Details
Speed at contact is over maximum
The tool has contacted the sensor at the higher speed than set in "#1509 TLM_Fmax (Maximum speed
toward tool setter)".
Remedy
Correct the feed rate to move the tool to the sensor.
M91 INVALID MEASUR. 9002
Details
Change of compensation No. or sub-side selection during measurement
A compensation No. or sub-side valid signal state has been changed while a sensor signal is ON or a
compensation amount is being written.
Remedy
Carry out the measurement again.
M91 INVALID MEASUR. 9003
Details
Error on response timing of sensor signal
A compensation No. has been changed at the same time as a sensor's response.
Remedy
Carry out the measurement again.
M92 IGNORE INT.LOCK
Details
Manual tool length measurement Interlock temporally canceled
"M01 Operation error 0005" and "M01 Operation error 0019", which occur at manual tool length
measurement, are temporally canceled. When a tool has contacted a sensor and "M01 Operation
error 0019" has occurred, tool escape is enabled by temporarily turning ON the interlock cancel
request. This alarm notifies that the interlock is disabled in the meantime.
Remedy
After carrying out the tool escape from the sensor, turn OFF the interlock temporary cancel signal for
manual tool length measurement.