Mitsubishi Electric M700VS Series Setup Manual page 271

Mitsubishi cnc
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#1238(PR)】 set10
bit0: Switch G36 function
Select the function, the automatic tool length measurement or arc thread cutting (CCW), to be
applied to G36 when the G code system 6 or 7 is selected.
0: Automatic tool length measurement
1: Arc thread cutting (CCW)
bit6: Switch absolute position detection alarm
Select the output destination of the absolute position detection alarm.
0: NC alarm 4 (AL4)
1: NC alarm 5 (AL5)
(Note) The absolute position detection alarm is listed in the alarm history regardless of this
bit7: Switch operation alarm
Select whether to enable the NC alarm 5 (AL5) signal output.
0: Disable NC alarm 5 (AL5) (default)
1: Enable NC alarm 5 (AL5)
【#1239(PR)】 set11
bit0: Coil switching method
Select the coil switching method.
0: Via PLC (Y189F).
1: NC internal processing. (Y189F is invalid.)
bit1: Handle I/F selection
Select the handle connection destination.
0: Use the handle connected to the encoder communication connector.
1: Use the remote I/O unit as a priority.
When HN341/HN342/HN351/HN391/HN392 is mounted, the handle connected to the operation
panel I/O unit will be used regardless of this parameter setting.
bit3: Polygon machining mode at reset
Select whether to cancel the polygon machining mode when reset is applied.
0: Not cancel.
1: Cancel.
bit4: Invalidate G51.1 phase command
Select whether to enable the phase control with the spindle-spindle polygon function.
0: Always enable. (When R is not commanded, it will be handled as R0.)
1: Enable only at the R command.
bit5: Door interlock spindle speed clamp valid
Select whether to enable the spindle clamp speed changeover by the PLC signal.
0: Disable
1: Enable
254
parameter setting.
All operation alarms will be output to NC alarm 4 (AL4).
All operation alarms will be recorded in the alarm history.
The following operation alarms will be output to NC alarm 5 (AL5), not to NC alarm 4 (AL4).
The operation alarms output to NC alarm 5 (AL5) will not be recorded in the alarm history.
- External interlock axis found (M01 0004)
- Cutting override zero (M01 0102)
- External feedrate zero (M01 0103)
- Block start interlock (M01 0109)
- Cutting block start interlock (M01 0100)
- Cutting interlock for spindle-spindle polygon (G51.2) (M01 1033)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents