Appendix 1 Explanation of Parameters
【#1314】 TapInp Synchronous tap in-position check width (tap axis)
Set the hole bottom in-position check width for synchronous tapping.
(Note) This parameter is valid only when "1" is set in "#1223 aux07/bit3" (synchronous tap in-position
---Setting range---
0.000 to 99.999
【#1316(PR)】 CrossCom Reference of common variables common for part systems
Select whether to use the common variables from #100100 to #800199.
0: Not use
1: Use
This parameter is valid only when the number of variable sets is set to 600 or more.
When this parameter is set to "1", variables from #100100 to #100110 will not be available as the
system variables for PLC data read function, and the setting of "#1052 MemVal" will be invalid.
【#1324(PR)】 Chop_R Chopping compensation value fixing method
Set the head No. of the R register used as the compensation amount save area during fixed
compensation amount method.
When the first number is an odd number, the operation message "Setting error" appears.
When the value overlaps with the chopping control data area, the operation message "Setting error"
appears.
---Setting range---
8300 to 9782
(Only the even number)
(Within backup area)
【#1326】 PLC Const Ext. Num PLC constant extension number
Set the number of PLC constant extension points.
---Setting range---
0 to 750
【#1327】 3D ATC type Tool change method specification
Select the tool change method for determining the tool to draw solids.
With 3D drawing, the tool will be changed by the method designated with this parameter, and then
the image will be drawn.
0: With one standby tool
1: With two standby tools
2: With no standby tool
【#1328】 TLM type Tool measurement standard positions election
Select the tool measurement method.
0: Use the machine position at TLM switch ON as 0.
1: Use the machine basic point as standard.
【#1329】 Emgcnt Emergency stop contactor shut-off time
Set the time taken for the drive section's main power to be shut-off when the confirmation of all the
axes' stop failed after the emergency stop state.
The contactor shut-off signal is output as soon as all the axes are confirmed stopped if the
confirmation is done prior to the set time.
When there is no safety observation option or "0" is set, the shut-off time will be 30(s).
---Setting range---
0 to 60 (s)
【#1330(PR)】 MC_dp1 Contactor weld detection device 1
When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b
contact signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
---Setting range---
0000 to 02FF (HEX)
270
check improvement) and "#1223 aux07/bit4" (synchronous tap hole bottom in-position check).