Movable Range During Inclined Axis Control - Mitsubishi Electric M700VS Series Setup Manual

Mitsubishi cnc
Table of Contents

Advertisement

8.2.2.5 Movable Range during Inclined Axis Control

By setting "#2063 OT_1Btype" to "3", the inclined axis control axis can be checked with the program coordinates using
the stored stroke limit IB/IC range setting ("#2061" and "#2062"). The stored stroke limit IB and IC cannot be used
together at this time.
By using this function with stored stroke limit I, the check can be carried out simultaneously with the actual axis and
program coordinate value. In this case, the range that does not fit into either of the following two prohibited ranges will be
the movable range.
2
4
: Moveable range
: Prohibited range
Point 3: "#2062 OT_1B+ (Soft limit IB+)" and
Point 4: "#2061 OT_1B- (Soft limit IB-)" are set with the coordinate values in the basic machine
coordinate system.
Points 1 and 2 are the prohibited range set with stored stroke limit I.
X
3
1
M700VS Series Setup Manual
8.2 Stored stroke limit (S/W OT)
y
Y
103