【#1281(PR)】 ext17
bit0: Switch manual high-speed reference position return in synchronous control
Select the movement of synchronized axes in manual high-speed reference position return.
0: Primary and secondary axes start the return synchronizing. Even when one axis stops at its
1: Primary and secondary axes start the return synchronizing, and when the primary axis stops at
bit3: Synchronous control operation setting
Select whether or not the positioning of secondary axis automatically aligns with that of primary axis
when the axis subject to synchronous control is changed from servo OFF to servo ON.
0: The positioning automatically aligns.
1: The positioning does not align.
bit5: High-speed synchronous tapping valid
Select whether to enable the high-speed synchronous tapping.
0: Disable
1: Enable
bit6 : Compensation method for external machine coordinate system/ball screw
thermal expansion during synchronization
Select the method of how to compensate the secondary axis when compensating
external machine coordinate system or ball screw thermal expansion during synchronization control.
The setting of this parameter will be validated when you select synchronous operation method by the
synchronization control operation method signal.
0: Primary axis and secondary axis are independently compensated.
1: Primary axis' compensation amount is applied to secondary axis.
bit7: Switch automatic high-speed reference position return in synchronous control
Select the movement of synchronized axes in automatic high-speed reference position return.
0: Primary and secondary axes start the return synchronizing, and when the primary axis stops at
1: Primary and secondary axes start the return synchronizing. Even when one axis stops at its
【#1282(PR)】 ext18
bit1: Condition of the reference position reached signal in synchronous control
This parameter switches only conditions of a master axis's reference position return reached signal
in synchronous operation. A slave axis's signal is output when the slave axis reaches the reference
position coordinate.
0: A master axis's reference position reached signal is output only when both of the master and
1: A master axis's reference position reached signal is output when the master axis reaches the
bit2: Measurement basic point for tool length measurement I (for L system only)
Select how to specify the measurement base point coordinate for manual tool length measurement I.
0: Specify the coordinate of "#2015 tlml-" as the measurement basic point (default).
1: Specify the workpiece coordinate system offset (modal) as the measurement basic point.
【#1283(PR)】 ext19
Not used. Set to "0".
【#1284(PR)】 ext20
bit0: Spindle speed clamp check
Select whether to check the spindle speed clamp under the constant surface speed control.
0: Check the spindle speed clamp.
1: Not check the spindle speed clamp.
(Note) This parameter is enabled when the parameter "#1146 Sclamp" is set to "1".
reference position, the other axis continues moving until it reaches its reference position.
the reference position, the secondary also stops. Thus, the relative position of the primary and
secondary is kept.
the reference position, the secondary also stops. Thus, the relative position of the primary and
secondary is kept.
reference position, the other axis continues moving until it reaches its reference position.
slave axes reach the reference position coordinate by a reference position return.
reference position coordinate.