MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#11016】 Expand_Rate Shape expansion rate
Set the model shape expansion rate to be used for 3D machine interference check. This parameter
is used for expanding a model shape to be used for 3D machine interference check. The
interference check is performed using a shape expanded by the amount of [Check length (mm) x
Shape expansion rate (%)].
---Setting range---
0 to 300(%)
【#11017】 T-ofs set at run
Select whether to enable the tool compensation amount setting and life value setting during
automatic operation and operation pause.
0: Disable
1: Enable
【#11018】 M password hold
Select whether to enable the "Machine user" password holding.When this is set to "1", the "Machine
user" password will be held.
0: Disable
1: Enable
【#11019】 2-system display 2-part system simultaneous display
Select whether to validate 2-part system simultaneous display on operation screen.
0: Display one part system on operation screen
1: Display two part systems simultaneously on operation screen
2: Display two part systems simultaneously (Display type 2) on operation screen
(Note 1) Unless you set "1" in two or more of "#1001 SYS_ON [1] to [4]", two-part system
【#11021】 PLC mesg disp type Format of PLC alarm and operator message
Select the format of PLC alarms and operator messages to be displayed on the bottom right of the
screen.
0: Display up to the first 40 characters.
1: If text is longer than 40 characters, divide it into two and display separately. (Classification No.
【#11022】 SRAM Output Type SRAM output type
Set the SRAM output type.
(Note) In M700 Series, the conventional SRAM output type is set regardless of the setting of this
parameter.
0: The latest SRAM output type is set.
1: The conventional SRAM output type is set.
【#11023】 G33.n Drn G33.n dryrun
Select whether to enable dry run in C axis interpolation type thread cutting. The standard setting is
"0".
0: Enable
1: Disable
【#11024】 G33.n fhd G33.n feed hold
Select whether to enable feed hold in C axis interpolation type thread cutting. The standard setting is
"0".
0: Disable
1: Enable
284
simultaneous display will fail regardless of this parameter.
is displayed together)
(Not compatible with F3 and versions older than F3.)
(Compatible with F3 and versions older than F3.)