【#12896】 aux_PSW13dog2 PSW13 area setting 2
Set "PSW13 area setting" 1 and 2 to specify the area where the position switch 13 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12897】 aux_PSW14dog1 PSW14 area setting 1
Set "PSW14 area setting" 1 and 2 to specify the area where the position switch 14 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12898】 aux_PSW14dog2 PSW14 area setting 2
Set "PSW14 area setting" 1 and 2 to specify the area where the position switch 14 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12899】 aux_PSW15dog1 PSW15 area setting 1
Set "PSW15 area setting" 1 and 2 to specify the area where the position switch 15 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12900】 aux_PSW15dog2 PSW15 area setting 2
Set "PSW15 area setting" 1 and 2 to specify the area where the position switch 15 will turn ON when
the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the position
switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12910】 aux_push Stopper amount
Set the command stroke of the stopper operation in the stopper positioning.
---Setting range---
0.000 to 359.999(° or mm)
【#12911】 aux_pusht1 Stopper standby time
Set the standby time from the stopper starting coordinate positioning to the stopper operation start in
the stopper positioning.
---Setting range---
0 to 9999(ms)