MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#10921】 Call wait time
Set the call back waiting time.
Default value: 0
This parameter is used as both Anshin-net parameter 2 and MTB-net parameter 2.
---Setting range---
0 to 90 (s)
【#10922】 Machine Num
Set the machine's serial number as information for the machine tool builder to recognize the
machine. This parameter is supposed to be input by the machine tool builder (when shipping or
when starting the machine tool builder network). If this is set to blank, the system cannot connect
with remote diagnosis tool kit.
---Setting range---
Within 15 characters (one-byte alphanumeric characters)
【#10951(PR)】 Condition kind 1
Set the condition (alarm or PLC signal) for the automatic notification of alarms.
Set the alarm type for alarm, device (register) name for PLC signal.
<Alarm>
Operation alarm (Mxx)
Stop code (Txx)
Servo alarm (Sxx)
Spindle servo alarm (Sxx)
System alarm (Zxx)
Absolute position detection alarm (Zxx)
Emergency stop (EMG)
Auxiliary axis servo alarm (Sxx)
Auxiliary axis absolute position detection alarm (Zxx)
Auxiliary axis OP error (Mxx)
Auxiliary axis MCP alarm (Yxx)
Computer link error (Lxx)
Operation error (Exx)
User PLC alarm (PLxx)
<Device (resister)>
1-bit data ... X,Y,U,W
16-bit data ... R
(Note 1) Set "0" to cancel (set blank for) any setting of #10951 to #10970, "Condition kind" 1 to 10
---Setting range---
Within 5 characters
【#10952(PR)】 Condition num 1
Set the condition (alarm or PLC signal) for the automatic notification of alarms.
Set the alarm No. for alarm, status value for PLC signal.
(Note) Set "0" to cancel (set blank for) any setting of #10951 to #10970, "Condition kind" 1 to 10 and
---Setting range---
Within 4 characters
462
and "Condition num" 1 to 10.Input "00" when setting "0" for "Condition num". When either of
"Condition kind" or "Condition num" is canceled, the condition will not be available for the
automatic notification of alarms.
"Condition num" 1 to 10.Input "00" to set "Condition num" to "0".When either of "Condition kind"
or "Condition num" is canceled, the condition will not be available for the automatic notification
of alarms.