Appendix 1 Explanation of Parameters
【#24132+15(m-1)】 CNm receive size Receive buffer size
Set the allocation of the buffer memory size to the local station, standby master station and
intelligent device station when in transient transmission.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
Set "0" when no setting is required.
(Note) The total size of the send/receive buffers must be 4096 (words) or less.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0, 64 to 4096 (words)
【#24133+15(m-1)】 CNm auto bfr size Automatic update buffer size
Set the allocation of the buffer memory size to the local station, standby master station and
intelligent device station when in transient transmission.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
Set "0" when no setting is required.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0, 128 to 4096 (words)