MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#8158】 Init const sur spd
Select the initial state after power-ON.
0: Constant surface speed control cancel mode.
1: Constant surface speed control mode.
【#8159】 Synchronous tap
Select whether to use the floating tap chuck in G74 and G84 tap cycles.
0: With a floating tapping chuck
1: Without a floating tapping chuck
【#8160】 Start point alarm
Select an operation when the operation start point cannot be found while moving to the next block of
G117.
0: The auxiliary function is enabled after the block for the movement has finished.
1: The program error (P33) occurs.
【#8173】 Hold intr amount
Select whether to clear or hold the interruption amount after the "NC reset 1 (or 2)" signal is ON
when the manual ABS switch is OFF.
0: Clear (Reset the coordinate deviation due to the interruption)
1: Hold
【#8201】 AX. RELEASE
Select the function to remove the control axis from the control target.
0: Control as normal.
1: Remove from control target.
【#8202】 OT-CHECK OFF
Select whether to enable the stored stroke limit II function set in #8204 and #8205.
0: Enable
1: Disable
【#8203】 OT-CHECK-CANCEL
When the simple absolute position method ("#2049 type" is "9") is selected, the stored stroke limits I,
II (or IIB) and IB can be disabled until the first reference position return is executed after the power is
turned ON.
0: Enable (according to #8202)
1: Temporarily cancel
(Note) "#8203 OT-CHECK-CANCEL" affects all the stored stroke limits.
【#8204】 OT-CHECK-N
Set the coordinates of the (-) direction in the movable range of the stored stroke limit II or the lower
limit coordinates of the prohibited range of stored stroke limit IIB.
If the sign and value are the same as #8205, the stored stroke limit II (or IIB) will be invalid.
If the stored stroke limit IIB function is selected, the prohibited range will be between two points even
when #8204 and #8205 are set in reverse. When II is selected, the entire range will be prohibited if
#8204 and #8205 are set in reverse.
---Setting range---
-99999.999 to 99999.999 (mm)
【#8205】 OT-CHECK-P
Set the coordinates of the (+) direction in the movable range of the stored stroke limit II or the upper
limit coordinates of the prohibited range of stored stroke limit IIB.
---Setting range---
-99999.999 to 99999.999 (mm)