Mitsubishi Electric M700VS Series Setup Manual page 190

Mitsubishi cnc
Table of Contents

Advertisement

【#8711】 TLM L meas axis
Set the tool length measurement axis.
Set the "#1022 axname2" axis name.
---Setting range---
Axis name
(Note) If the axis name is illegal or not set, the 3rd axis name will be set as default.
【#8712】 TLM D meas axis
Set the tool diameter measurement axis.
Set the "#1022 axname2" axis name.
---Setting range---
Axis name
(Note) If the axis name is illegal or not set, the 1st axis name will be set as default.
【#8713】 Skip coord. Switch (For M system only)
Select the coordinate system for reading skip coordinate value.
Select whether to read the skip coordinate in the workpiece coordinate system or in the feature
coordinate system during inclined surface machining command.
Select whether to read the skip coordinate in the workpiece coordinate system or in the workpiece
installation coordinate system during workpiece installation error compensation.
0: Workpiece coordinate system
1: Feature coordinate system/Workpiece installation coordinate system
【#8880】 Subpro stor D0: dev
Select the storage destination (device) for the subprogram.
M:Memory, G:HD(Note), F:FD(Note), R:Memory card, D:Data server(Note)
(Note) This is available only with M700/M700VW Series.
When D0 is designated at a subprogram call, the subprogram to be called will be searched from the
device selected with this parameter.
(Example) M98 P (program No.), D0
-> Device: "#8880 Subpro stor D0: dev" device
Directory: "#8881 Subpro stor D0: dir" directory
The device and directory above will be searched.
(Note 1) When the called subprogram is not found in the selected storage destination, a program
(Note 2) When D0 to D4 is not designated at a subprogram call, the subprogram will be searched
【#8881】 Subpro stor D0: dir
Select the storage destination (directory) for the subprogram.
When D0 is designated at a subprogram call, the subprogram to be called will be searched from the
directory selected with this parameter.
Refer to "#8880 Subpro stor D0: dev".
---Setting range---
Directory 48 characters
error will occur.
from the memory.
M700VS Series Setup Manual
Appendix 1.1 User Parameters
173

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents