Appendix 1 Explanation of Parameters
【#7634】 PSW14 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
(Note) This parameter is valid only when "1" set in "#7500 Pcheck".
【#7641】 PSW15 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
【#7642】 PSW15 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
1st part system device: X1D0E
2nd part system device: X1D2E
---Setting range---
-99999.999 to 99999.999 (mm)
【#7643】 PSW15 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
1st part system device: X1D0E
2nd part system device: X1D2E
---Setting range---
-99999.999 to 99999.999 (mm)
【#7644】 PSW15 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area checking,
i.e., whether to use the command type machine position or detector feedback position, for each
position switch point.
0: Use the command type machine position as the machine position for position switch area
1: Use the detector feedback position as the machine position for position switch area checking.
(Note) This parameter is valid only when "1" set in "#7500 Pcheck".
【#7651】 PSW16 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
【#7652】 PSW16 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to
the PLC.
1st part system device: X1D0F
2nd part system device: X1D2F
---Setting range---
-99999.999 to 99999.999 (mm)