【#2051】 check Check
Set the tolerable range of travel distance (deviation distance) while the power is turned OFF.
If the difference of the positions when the power is turned OFF and when turned ON again is larger
than this value, an alarm will be output.
Set "0" to omit the check.
---Setting range---
0 to 99999.999 (mm)
【#2054】 clpush Current limit (%)
Set the current limit value during the stopper operation in the dogless-type absolute position
detection.
The setting value is the ratio of the current limit value to the rated current value.
---Setting range---
0 to 100 (%)
【#2055】 pushf Push speed
Set the feedrate for the automatic initial setting during stopper method.
---Setting range---
1 to 999 (mm/min)
【#2056】 aproch Approach
Set the approach distance of the stopper when deciding the absolute position basic point with the
stopper method.
After using stopper once, the tool returns with this distance, and then use stopper again.
---Setting range---
0 to 999.999 (mm)
【#2057】 nrefp Near zero point +
Set the positive direction width where the near reference position signal is output.
When set to "0", the width will be equivalent to the grid width setting.
(Note) When "#1240 set12/bit2" is ON, a magnification (C: 10-fold, D: 100-fold, E:1000-fold)
---Setting range---
0 to 999.999 (mm)
(Input setting increment applied)
【#2058】 nrefn Near zero point -
Set the negative direction width where the near reference position signal is output.
When set to "0", the width will be equivalent to the grid width setting.
(Note) When "#1240 set12/bit2" is ON, a magnification (C: 10-fold, D: 100-fold, E:1000-fold)
---Setting range---
0 to 999.999 (mm)
(Input setting increment applied)
【#2059】 zerbas Select zero point parameter and basic point
Select which is to be the zero point coordinate position during absolute position initial setting.
0: Position where the axis was stopped.
1: Grid point just before stopper.
【#2061】 OT_1B- Soft limit IB-
Set the coordinate of the lower limit of the area where the stored stroke limit IB is inhibited.
Set a value from zero point in the basic machine coordinate system.
If the same value (non-zero) with the same sign as that of "#2062 OT_IB+" is set, the stored stroke
limit IB function will be disabled.
---Setting range---
-99999.999 to 99999.999 (mm)
corresponding to the input setting increment ("#1003 iunit") will be applied to the setting value.
corresponding to the input setting increment ("#1003 iunit") will be applied to the setting value.
M700VS Series Setup Manual
Appendix 1.3 Axis Specifications Parameters
301