【#13018(PR)】 SP018 SPEC2 Spindle specification 2
Select the spindle specification.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-A :
Not used. Set to "0".
bit 9 : mpg Earth fault detection
0: Disable
Set "0" and it is constantly "Enable" for MDS-D-SPJ3 Series.
bit 8 : spsu Speed setting unit
0: r/min
bit 7-6 :
Not used. Set to "0".
bit 5 : mkch Coil switch function
0: Disable 1: Enable
bit 4-2 :
Not used. Set to "0".
bit 1 : oplp Open loop
0: Disable 1: Enable
bit 0 :
Not used. Set to "0".
【#13019(PR)】 SP019 RNG1 Sub side detector resolution
[For semi-closed loop]
Set the same value as SP020 (RNG2). (Refer to the explanation of SP020.)
[For full-closed loop]
Set the number of pulses per revolution of the speed detector.
When using ABZ pulse encoder, used this with SP097(RNG1ex).
E.g.: The setting for ABZ pulse encoder "OSE-1024-3-15-68"
---Setting range---
-32768 to 32767 (kp/rev)
When using SP097: (p/rev)
1: Enable (standard)
1: 4 r/min
SP019 = 4096
SP097 = -1