Mitsubishi Electric M700VS Series Setup Manual page 288

Mitsubishi cnc
Table of Contents

Advertisement

【#1331(PR)】 MC_dp2 Contactor weld detection device 2
When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b
contact signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
---Setting range---
0000 to 02FF (HEX)
【#1332(PR)】 F-bus init delay Fieldbus communication error invalid time
Tuning the power ON, start the communication, and then set the time where Fieldbus
communication error is not detected.
Set this in 0.1 second increment.
---Setting range---
0 to 255 (0.1s)
Standard: 0
【#1333】 LMC restrain Lost motion compensation restraint in handle mode
Select whether to restrain the lost motion compensation in handle mode.
0: Restrain
1: Not restrain
【#1334】 DI/DO refresh cycl DI/DO refresh cycle
Select the DI/DO refresh cycle.
0: Standard mode
1: High-speed mode 1
2: High-speed mode 2
(Note 1) This setting is valid only for M700VW/M700VS/M700/M70V Series and M70(typeA).
(Note 2) The speed may not be high if number of ladder steps is excessive.
(Note 3) If high-speed mode is selected, the fine segment processing performance may degrade.
【#1335】 man_smg Manual feed acceleration/deceleration selection
Select the acceleration/deceleration mode in jog feed, incremental feed and manual reference
position return (when rapid traverse signal OFF).
0: Acceleration/Deceleration for rapid traverse
1: Acceleration/Deceleration for cutting feed
【#1336(PR)】 #400_Valtype #400 address variable type
Select whether the #400-level variables are used as machine tool builder macro variables or as
common variables.
0: #400 to #449 are not available; #450 to #499 are used as machine tool builder macro variables.
1: #400 to #499 are used as common variables
(Note) 700 sets or more of common variables are required for using #400 to #499 as common
【#1338(PR)】 rev data save trg Trigger switching to save arbitrary reverse run data
Select the condition to start/stop saving reverse run data.
0: Start when the reverse run control mode signal is turned ON. Stop when turned OFF.
1: Start when the reverse run control mode signal is ON and macro interrupt is valid (M96/ION).
【#1339(PR)】 MC_dp3 Contactor weld detection device 3
When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b
contact signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
---Setting range---
000 to 02FF (HEX)
"Standard mode" is applied to M70 (typeB) regardless of this parameter.
variables. If this parameter is set to "1" while the number of common variables is set to less
than 700, this parameter setting will be regarded as "0".
Stop when the reverse run control mode signal is OFF or macro interruption is finished (M97/
IOF) (compatible with M500M).
M700VS Series Setup Manual
Appendix 1.2 Base Specifications Parameters
271

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents