MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#2146】 Blf_L1 Reference distance for position-dependent increasing-type backlash
compensation 1
Set the distance for specifying the compensation change rate in position-dependent increasing-type
backlash compensation.
Blf_E1
Blf_E2
When "#2146 Blf_E1" is set to "0", the position-dependent increasing-type backlash compensation
function will be disabled.
---Setting range---
0.000 to 99999.999 (mm)
【#2147】 Blf_L2 Reference distance for position-dependent increasing-type backlash
compensation 2
Set the distance for specifying the compensation change rate in position-dependent increasing-type
backlash compensation.
Blf_E1
Blf_E2
When "#2146 Blf_E1" is set to "0", the position-dependent increasing-type backlash compensation
function will be disabled.
---Setting range---
0.000 to 99999.999 (mm)
【#2148】 Blf_E1 Reference amount of position-dependent increasing-type backlash
compensation 1
Set the compensation amount for specifying the compensation change rate in position-dependent
increasing-type backlash compensation.
Blf_E1
Blf_E2
When "#2146 Blf_E1" is set to "0", the position-dependent increasing-type backlash compensation
function will be disabled.
---Setting range---
0 to 9999999 (Machine error compensation unit)
312
Blf_L2
Blf_L1
Blf_L2
Blf_L1
Blf_L2
Blf_L1

Hide quick links: