Mitsubishi Electric M700VS Series Setup Manual page 404

Mitsubishi cnc
Table of Contents

Advertisement

【#13079】 SP079 IQG Q axis current gain
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13080】 SP080 IDG D axis current gain
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13081】 SP081 IQAL Q axis current lead compensation low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 20480
【#13082】 SP082 IDAL D axis current lead compensation low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 20480
【#13083】 SP083 IQGL Q axis current gain low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13084】 SP084 IDGL D axis current gain low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is selected.
The setting value is determined by the motor's electrical characteristics so that the value is fixed to
each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13085】 SP085 LMCk Lost motion compensation 3 spring constant
Set the compensation amount for the spring constant when using lost motion compensation type 3.
When not using, set to "0".
---Setting range---
0 to 32767 (0.01%/0.001゜)
M700VS Series Setup Manual
Appendix 1.5 Spindle Parameters
387

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents