【#10913(PR)】 Num arrival call 5
Set the caller's No.: the other party's telephone No. that is used for INIT authentication.
Enter from the area code for domestic calls.
Enter from the communication company No. for international calls.
This is used to distinguish between received calls from Call Center and those from machine tool
builder.
A hyphen "-" can be used as a delimiting character.
---Setting range---
Within 28 characters
【#10914】 Auto select anet
Set whether to change to the Anshin-net screen when a call is automatically dispatched from the NC.
(Currently not used.)
0: Not change
1: Change
【#10915】 Num retry
Set the number of times to retry when a control command transmission error occurs.
Standard setting: 3
---Setting range---
0 to 255
【#10916】 Command time out
Set the timeout time for reception command standby.
Standard setting: 30 (s)
---Setting range---
0 to 65535 (s)
【#10917】 Frequ of redial
Set the number of times to redial.
Standard setting: 3
This parameter is used as both Anshin-net parameter 2 and MTB-net parameter 2.
---Setting range---
0 to 255
【#10918】 Interval of redial
Set the redial interval.
Standard setting: 100 (s)
This parameter is used as both Anshin-net parameter 2 and MTB-net parameter 2.
---Setting range---
0 to 65535 (s)
【#10919(PR)】 Modem connect port
Select the modem connection port.
1: Port 1
2: Port 2
This parameter is used as both Anshin-net parameter 2 and MTB-net parameter 2.
【#10920】 Dial mode select
Select the dialing method.
0: Fixed by modem (default)
1: Dial with tone (push) method
2: Dial with pulse (dial) method
This parameter is used as both Anshin-net parameter 2 and MTB-net parameter 2.
Appendix 1.15 Anshin-net Parameters 2/ MTB-net Parameters 2