The production of machines with 840D sl requires a basic commissioning of the SINAMICS,
generally designated as "System configuration". The system configuration can be performed
with CMC either as "Automatic configuration" or as "User-specified topology."
When the system configuration is configured in the CMC package, all the data sets and
optimization data in the step tree required within a series of modular machines in the maximum
machine configuration can be specified. The package is adapted to the specific version of a
modular machine either initially during the configuring or when the package is being executed
on the machine – either manually or using configuration files.
6.7.2
SINAMICS device configuration with Automatic configuration or user-specified
topology
Applications
With regard to device configuration of the SINAMICS, a general distinction is made between
three use cases that CMC supports:
1. SINAMICS was commissioned previously with SINUMERIK Operate or with different
commissioning software. The existing drive data can be checked with a CMC package via
"Initial state" (online access) on the dialog page "System configuration" under "DRV..." in
the drive archive data, including the topology. In addition, a further configuration or
optimization of the SINAMICS can be made.
2. The maximum configuration of the SINAMICS is wired on the machine, but the SINAMICS
has not yet been commissioned or configured. Using a CMC package, the "Automatic
configuration" under "DRV archive data/drive configuration" is selected from the "System
configuration" dialog page. The checks, configurations or optimizations listed in item 1 in
the same package are then performed.
3. Not all the SINAMICS components provided for the maximum configuration of the machine
have already been wired on the machine. For example, DQI/SMI motors are still missing.
The SINAMICS has not yet been commissioned and configured. Using a CMC package,
the "User-specified topology" under "DRV archive data/drive configuration" is executed
from the "System configuration" dialog page. The user-defined topology file is a SINAMICS
offline topology package (SOT) that contains the topology in the final configuration of the
machine. The checks, configurations or optimizations listed in item 1 in the same package
are then performed.