Package Execution On Ncu/Ppu From The Compactflash Card; Package Execution On The Ncu/Ppu From The Network - Siemens SINUMERIK 840D sl Operating Manual

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Expert
4.12 Package execution
If there are several packages in the start folder, they will be provided on the Package selection
dialog page.
If you select a package other than the default package for execution, clicking the Next button
ends the default package and starts the newly selected package.
This causes the VNC server of the NCU/PPU to restart. In this context, there is a loss of
connection to all VNC viewers.
The VNC viewer running on the TCU is then automatically ended and restarted.
An external VNC viewer running under Windows on your PC/PG or the PCU might possibly
have to be restarted if no automatic connection attempts were set for this.
4.12.3.3

Package execution on NCU/PPU from the CompactFlash card

Under some circumstances, Linux packages can be executed from the CF card of the NCU/
PPU that contains the CNC software.
Requirements
The following requirements apply:
● The CompactFlash card must contain a bootable CNC system.
● Fresh installation or upgrading is not permissible.
● The Linux package <name> can be stored under any path <path> on the CompactFlash
card. We recommend storage according to the responsibility below "/card/oem" or "/card/
user".
Procedure
1. Create an "sci.ini" file with the entry: "Start=<path>/<name>".
Example: Start=/card/user/Test.usz
2. Save this file in the "/<responsible>/system/etc" folder of the CompactFlash card.
Whereby, <responsible> can be "siemens", "addon", "oem" or "user".
3. Activate the "Off/On" main switch.
4. Follow the instructions of the package dialogs.
Note
The "sci.ini" file is deleted from the package once it has been started. This will ensure that
a package is not unintentionally executed several times.
4.12.3.4

Package execution on the NCU/PPU from the network

Linux packages can also be executed from a network drive.
410
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE