Advertisement

Setting disabled
Yes
No
Preselection of the offline archive
Dialog scripts
In the "Dialog scripts" property, "Scripts" entry, click the
dialog. Here you can edit scripts that are to be executed at selectable times during package
execution.
You can find detailed information on the dialog scripts in the section with the same name
"Dialog scripts (Page 145)".
You can find an example of the dialog scripts for the system configuration in "Examples of
scripts in dialog pages (Page 149)".
4.4.2.25

System configuration (package execution)

In this dialog, specify which data of the NC, PLC (HW) and DRV subsystems is used as output
data for the package execution.
This dialog corresponds with regard to the drive commissioning to the "SINAMICS topology"
dialog.
If the "System configuration" dialog page is executed in editing mode "Manual", the "Origin of
data" can be adapted for every area if the project engineer has not locked this.
In the case of "Offline archive", archives must be selected that were either transferred with the
package, are located next to the package (prefix "./") or are inserted at any location by clicking
the
Note
If, during package execution, a jump is made to the "System configuration" dialog page via
"Back", then the archives backed up there are reused, and changes that have possibly already
been made are rejected.
Example
Example: Archive next to the package:
./myPath/myArchive.arc
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
The selection at "Origin of data" can be blocked by the project engineer via this
option in order to prevent changes by the operator during the package execu‐
tion.
At "Preselection of the offline archive", a SINUMERIK archive can be inserted,
linked or preselected from the list.
Alternatively, enter the path of a file which is located next to the package /
<Path>/<File>,
e.g. "./DRV-data.arc".
Note
When data for "Offline archive" is entered in the step tree via components, an
archive from the overall reset state must be saved here or the "Origin of the
data" must be set to "Overall reset".
("Search") button.
Create MyConfig - Expert
4.4 Project folder
button to call the "Dialog scripts"
193