Package Execution; Introduction - Siemens SINUMERIK 840D sl Operating Manual

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Note
Also observe the transfer of rights for "Rights without password"
If you have also changed the rights of the "Default password" for the "Rights without password"
in your source for the transfer (project or component) and also want to transfer this change,
you must also activate this password for the transfer. Generally, "Replace" makes sense as
action.
This means that if you create new passwords in your password lists and transfer rights from
"Rechte ohne Kennwort", you remove these rights from the "Rights without password".
Ensure during transfer that you transfer not only your new passwords, but also the "Rights
without password", because otherwise this would still retain all rights and your components
would not be protected.
4.12

Package execution

4.12.1

Introduction

How can Create MyConfig packages be processed or executed?
Create MyConfig packages can be deployed with Expert for Windows and Linux systems.
For the Linux operating system on the NCU/PPU, Expert generates a file with the extension
""*.usz"" (Linux package) and for the Windows operating system on the PCU, PG or PC, a file
(Windows package) with the extension ""*.exe"".
The following sections describes the procedure for the Windows and Linux operating systems.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Action
The desired actions are defined via the checkboxes:
● Add
The password is added to the target component with the associated rights.
If the password already exists, the rights are overwritten additively.
● Replace
If an identical password is found in the target component, only the rights of the source
password are applied.
If a password to be transferred to the target component does not exist, no action will be
performed.
● Delete
The password is deleted in the target components.
The first line "Rights without password" cannot be deleted.
With the OK button, transfer of the selected passwords
formed according to the selected action
With the Cancel button, you discard the settings and close the dialog.
to the selected components is per‐
.
Create MyConfig - Expert
4.12 Package execution
405