SAMSUNG DCS
TECHNICAL MANUAL
MMC 200:
DESCRIPTION:
Used to open and close customer level programming. If programming is not opened and an attempt is made
to access a system MMC, the error message [NOT PERMIT] will be displayed.
A four digit passcode is required to access this MMC. Each digit can be 0-9. When opened, this MMC
enables access to all MMCs allowed in MMC 802 Customer Access MMC Number.
PROGRAM KEYS
UP & DOWN
KEYPAD
SPK
TRSF
ACTION
1.
Press TRSF 200
Display shows
2.
Enter passcode
Correct code shows
Incorrect code shows
3.
Press UP or DOWN arrow key to
select ENABLE or DISABLE and
Press RIGHT soft key
Dial 1 for ENABLE, dial 0 for DISABLE
4.
Press SPK to advance to MMC entry level
and
press UP or DOWN key to select MMC
Enter MMC number and press RIGHT soft
key to enter MMC.
5.
To log out press TRSF key.
DEFAULT DATA:
RELATED ITEMS:
Page 42 of 280 DCS & DX I&M
Open Customer Programming
Select open or closed
Used to enter passcode
Save data and advance to next MMC
Exit Programming
OR
OR
CLOSED
MMC 201 CHANGE CUSTOMER PASSCODE
MMC 802 CUSTOMER ACCESS MMC NUMBER
PROGRAMMING
DISPLAY
ENABLE CUS. PROG.
PASSCODE : _
ENABLE CUS. PROG.
PASSCODE :∗ ∗ ∗ ∗
ENABLE CUS. PROG.
DISABLE
ENABLE CUS. PROG.
PASSWORD ERROR
ENABLE CUS. PROG.
ENABLE
212: ALARM RING
SELECT PROG. ID
August 2001
SECTION

Advertisement