TECHNICAL MANUAL
MMC 800:
DESCRIPTION:
Used to open and close technician level programming. If programming is not opened and an attempt is made
to access a system MMC, the error message "ACCESS DENIED" will be displayed.
A four digit passcode is required to access this MMC. Each character can be digits 0-9 or *. When opened,
this MMC enables access to all MMCs.
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
ACTION
1.
Press TRSF 800
Display shows
2.
Enter passcode
Correct code shows
Incorrect code shows
3.
Press UP or DOWN to open or close
Enter 1 to enable or enter 0 to disable,
press RIGHT soft key to move to
tenant number and enter
tenant number (1-2)
4.
Press SPK to advance to MMC entry level
5.
Enter the MMC desired (eg., 209)
6.
To log out and return to MMC 800 ,
press UP or DOWN key to select
DISABLE TENANT :1
Press SPK then TRSF to return to normal
display
Programming option will time out
DEFAULT DATA:
RELATED ITEMS:
Page 268 of 287 Updated I&M
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
OR
OR
NONE
NONE
Enable Technician Program
DISPLAY
ENABLE TECH. PROG
PASSCODE :
ENABLE TECH. PROG
PASSCODE : 4321
ENABLE TECH. PROG
DISABLE TENANT : 1
ENABLE TECH. PROG
PASSCODE ERROR
ENABLE TECH. PROG
ENABLE TENANT : 1
ENABLE TECH. PROG
ENABLE TENANT : 1
801 : TEC. PASSCODE
SELECT PROG. ID
209 : AOM MASTER
AOM NOT EXIST
PROGRAMMING
SECTION
May 2002