Tracam; Jvc; Vst - Rs-485 - Unidirectional - Honeywell MAXPRO-Net Hardware Installation Manual

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

7.10.28

Tracam

Note: The Tracam protocol is effective from version 2.10 firmware onwards
Format switch SW1
Mode switch
Data connection
Tracam RS-485 receivers may be daisy chain or star connected with up to 16 receivers
supported per RD316 Module. Field cables may connect to DB25 pin pair 7(B) and
20(A) or pin pair 8(B) and 21(A).
Notes:
7.10.29

JVC

Note: The JVC protocol is effective from version 2.10 firmware onwards
Format switch SW1
Mode switch
Data connection
JVC RS-485 receivers may be daisy chain or star connected with up to 16 receivers
supported per RD316 Module. Field cables may connect to DB25 pin pair 7(B) and
20(A) or pin pair 8(B) and 21(A).
7.10.30
VST – RS-485 – Unidirectional
Note: The VST Unidirectional and bi-directional protocol is effective from version 2.15
firmware onwards.
Format switch SW1
Mode switch
Data Connection
VST RS-485 receivers may be connected with up to 16 receivers supported per RD-316
module. Field cables may connect to DB25 pin pair 7(B) and 20(A) or pin pair 8(B) and
21(A).
Rev. C
1 - 4 OFF
SW2
3, 6 - 8 OFF
SW2
1, 2, 4, 5 ON
Auxiliary Output 1 is used for the "Drive Forward " command.
Auxiliary Output 2 is used for the "Drive Reverse" command.
1 - 4 OFF
SW2
1, 2, 6 – 8 OFF
SW2
3, 4, 5 ON
1-4 OFF
SW2
1,6-8 OFF
2-5 ON
7.10-15
HMXMU001018
10/06

Advertisement

Table of Contents
loading