11.17 HMX128 MODULES WITH 3 DIP SWITCHES (OLDER VERSIONS)

SW2
1 - ID100
2 - ID200
3 - ID300
4 - OFF = CC
ON = EOL mode
SW3
1-7 - ID 1-99
8
- 19.2K Baud
[S1] This is a system reset button for the MX128 Control Card. This is used only for
Rev. C
MX128 LAYOUT
SW1
MODE
GA1
GA2
PTZ
GA3
GA4
CONTROL
GB1
GB2
PROTOCOL
GB3
GB4
CARD DATA
+
+
SERIAL DATA
+
POWER
+
PTZ DATA
+
VIDEO FAIL
S1
ID 100
SW2
ID 200
ID 400
EOL
SUBRACK
ADDRESS
ID 1
SW3
ID 2
ID 4
ID 8
ID 16
ID 32
ID 64
BAUD
commissioning and troubleshooting.
SW1
GA1
GA2
GA3
or
or
or
GB1
GB2
GB3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
11-15
GA4
Protocol
or
GB4
OFF
Diamond FastScan/SmartScan
OFF
Diamond SmartScan III/KD6 onwards
OFF
MAXPRO RS-485
OFF
MAXPRO AF-485
OFF
Panasonic
OFF
Pelco AD Format
OFF
Vicon Std
OFF
Vicon Extended
OFF
Star Micronics
OFF
VIDEV
OFF
VCL
ON
Pelco P Format
ON
JVC
ON
Speeddome
ON
Kalatel
ON
Baxall 7000 Series