7.10.14

Panasonic - WV-CS850 Series

Format switch SW1
19.2Kbps
Mode switch
or
9600bps
Mode switch
Note: WV-CS850 Protocol was introduced in version 2.07 firmware. This version only
supports 19.2Kps. However, version 2.08 firmware and above does support
9600bps as well as 19.2Kbps.
Data connection
Panasonic RS-485 receivers may be connected with up to 16 receivers supported per
RD-316 module. Field cables may connect to DB25 pin pair 7(B) and 20(A) or pin pair
8(B) and 21(A). The WV-CS850 should be set for
4-wire duplex operation.
Connection details from a Panasonic WV-CSR600/CS850 dome to the I/O slot of a
subrack (populated with a RD-316 module) :-
Rev. C
1 - 4 OFF
SW2
2, 4 - 8 OFF
SW2
1, 3 ON
SW2
1, 4 - 8 OFF
SW2
2, 3 ON
7.10-8