7.10.17

Star/Chugai/Sanyo SMD12P, SMD20P, VCC9200P

Format switch SW1
Mode switch
Data connection
Star/Chugai/Sanyo RS-485 receivers may be daisy chain or star connected with up to 16
receivers supported per RD-316 Module. Field cables may connect to DB25 pin pair
7(B) and 20(A) or pin pair 8(B) and 21(A).
7.10.18

Mark Mercer

Format switch SW1
Mode switch
Data connection
Mark Mercer RS-485 receivers may be daisy chain or star connected with up to 16
receivers supported per RD-316 Module. Field cables may connect to DB25 pin pair
7(B) and 20(A) or pin pair 8(B) and 21(A).
7.10.19

Videv

Format switch SW1
Mode switch
Data connection
Videv RS-485 receivers may be daisy chain or star connected with up to 16 receivers
supported per RD-316 Module. Field cables may connect to DB25 pin pair 7(B) and
20(A) or pin pair 8(B) and 21(A).
7.10.20

VCL

Format switch SW1
Mode switch
Data connection
VCL RS-485 receivers may be daisy chain or star connected with up to 16 receivers
supported per RD-316 Module. Field cables may connect to DB25 pin pair 7(B) and
20(A) or pin pair 8(B) and 21(A).
Rev. C
1 - 4 OFF
SW2
1, 3, 4, 6 - 8 OFF
SW2
2, 5 ON
1 - 4 OFF
SW2
1, 5 – 8 OFF
SW2
2, 3, 4 ON
1 - 4 OFF
SW2
5 – 8 OFF
SW2
1 – 4 ON
1 - 4 OFF
SW2
2 – 4, 6 – 8 OFF
SW2
1, 5 ON
7.10-10