7.10.15

American Dynamics

Two formats are implemented. 2 byte suitable for single speed receivers, e.g. AD 1689,
and a 4 byte version suitable for Cobra domes.
2 Byte Manchester
Format switch SW1
Mode switch
4 Byte
Format switch SW1
Mode switch
Data connection
AD Manchester receivers may be daisy chain connected with up to 16 receivers
supported per RD316 Module.
Field cables may connect to DB25 pin pairs 22(A) & 9(B), 23(A) & 10(B), 24(A) & 11(B),
25(A), & 12(B).
Pin (A) is equivalent to AD pin designation White.
7.10.16

Philips/Burle

Format switch SW1
Mode switch
Data connection
Up to 16 Philips/Burle RS-232 receivers may be connected via suitable RS-485
converter(s) to a RD316 Module. Data communication to the receivers is simplex
requiring only a two-wire circuit. The RS-485/232 converter(s) may connect to D25 pin
pair 7(B) and 20(A) or pin pair 8(B) and 21(A). The RD-316 utilizes a data rate of
9600bps, wiring distances and topology should be carefully planned to ensure reliable
data transfer.
Rev. C
1 ON
SW1
2 - 4 OFF
SW2
1, 2, ON
SW2
3 - 8 OFF
1 ON
SW1
2 - 4 OFF
SW2
1, 2, 4 ON
SW2
3, 5 - 8 OFF
1 - 4 OFF
SW2
1 - 4, 6 - 8 OFF
SW2
5 ON