7.10.12
Vicon Extended
Format switch SW1
Mode switch
Data connection
Vicon RS-485 receivers may be connected with up to 16 receivers supported per RD-316
module. Field cables may connect to DB25 pin pair 7(B) and 20(A) or pin pair 8(B) and
21(A).
7.10.13
Panasonic - WV-CS600/WV-RM70, WV-CS600A/WV-RM70, and WV-CSR600
Format switch SW1
Mode switch
Data connection
Panasonic RS-485 receivers may be connected with up to 16 receivers supported per
RD316 module. Field cables may connect to DB25 pin pair 7(B) and 20(A) or pin pair
8(B) and 21(A).
The WV-RM70 should be set up at a data rate of 9600bps. All other settings should be
left at factory default values.
Note: It should be noted that some Panasonic receivers do not have preset view set
command capability via RS-485, and as such this function will not work. WV-
CS600A and later equipment supports this functionality.
Connection details from a Panasonic WV-CSR600 dome to the I/O slot of a subrack
(populated with a RD-316 module):
Rev. C
1 - 4 OFF
SW2
1 - 3, 5 - 8 OFF
SW2
4 ON
1 - 4 OFF
SW2
1, 2, 4 - 8 OFF
SW2
3 ON
7.10-7
HMXMU001018
10/06