7.15.8

Error Display

If a setup error, invalid DIP switch setting or function control error should occur, the
RD490 will flash the eight indicator LED's (at 0.5sec) to display the appropriate error
status.
All eight LEDs flashing in phase will indicate an error zero. Errors (1) to (8) are indicated
by all LEDs flashing with one LED out of phase corresponding to the error level.
Rev. C
Error Definitions
0
General error
1
Invalid Mode Selection
2
Device not found
3
User mode not defined
4
Incorrect type of user data
5
EEPROM write error
6
EEPROM overflowed
7
Format error in INTEL-HEX data
8
Not used
CAUTION: Once an error is displayed the RD490
module must be reset. Usually the module would be
removed to make DIP switch adjustments. Replacing the
module in the subrack causes it to be reset.