11.6 CUSTOMIZING YOUR CONFIGURATION

System configuration details are covered in the MAXPRO-Net Commissioning Manual
supplied with your system. There are, however, a number of items specific to the HD
Series which are detailed below.
11.6.1

Enabling Video Fail/Level Detection.

HD Series hardware includes video fail/level detection hardware. This may be enabled
by entering the appropriate value into the FSL field (Video Failed Detector Slot Number)
of the video input table within the SETMAX Configurator.
Values are as follows:
11.6.2

Pan/Tilt Control

As shipped, all video inputs are defined as cameras with pan/tilt control. During
commissioning, it is advantageous to disable pan/tilt control for fixed cameras or other
video sources not having control. (This provides for automatic operator feedback from
the system if control of a fixed camera is attempted). To disable pan/tilt control for a
particular camera, remove the entries from the CID, CSL and CSI fields in the Video
Input table within the SETMAX Configurator.
HMX32128 subracks have 8 ports for pan/tilt control. These are divided into two groups
- A & B.
Group A consists of ports 1 – 4, and group B ports 5 – 8. This allows two independent
PTZ control protocols to exist. For example ports 1 – 4 could be assigned to Diamond
protocol and ports 5 – 8 could be assigned to Maxpro protocol.
Rev. C
Physical Input Range
1- 32
33-64
65- 96
97-128
NOTE: In all other respects, video fail/level detection is
as detailed within the Commissioning Manual.
Slot Number
(FSL field in SETMAX)
11
12
13
14
11-3
HMXMU001018