Pelco - Coaxitron Interface Format; Maxpro - Rs-485 - Non Polling; Maxpro - Rs-485 - Polling; Vicon Standard - Honeywell MAXPRO-Net Hardware Installation Manual

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

7.10.8
PELCO – Coaxitron Interface Format
Format switch SW1
Mode switch
Note: Receiver addressing via the onboard DIP switch is true binary with a supported
range of 1 through 16 on each RD-316. Data rate is 4800bps.
7.10.9
Maxpro – RS-485 – Non Polling
Format switch SW1
Mode switch
Data connection
Maxpro RS-485 receivers may be connected with up to 16 receivers supported per
RD316 module. Field cables may connect to DB25 pin pair 7(B) and 20(A) or pin pair
8(B) and 21(A).
7.10.10
Maxpro – RS-485 – Polling
Format switch SW1
Mode switch
Data connection
Maxpro RS-485 receivers may be connected with up to 16 receivers supported per RD-
316 module. Field cables may connect to DB25 pin pair 7(B) and 20(A) or pin pair 8(B)
and 21(A).
7.10.11

Vicon Standard

Format switch SW1
Mode switch
Data connection
Vicon RS-485 receivers may be connected with up to 16 receivers supported per RD-316
module. Field cables may connect to DB25 pin pair 7(B) and 20(A) or pin pair 8(B) and
21(A).
Rev. C
1 - 4 OFF
SW2
2, 4, 6 - 8 OFF
SW2
1, 3, 5 ON
1 - 4 OFF
SW2
2, 3, 5 - 8 OFF
SW2
1, 4 ON
1, 2 OFF
SW1
3, 4 ON
SW2
1, 3, 5 - 8 OFF
SW2
2, 4 ON
1 - 4 OFF
SW2
4 - 8 OFF
SW2
1 - 3 ON