7.10 RD316 MODULE - RS-422/485 PTZ SITE TRANSMITTER MODULE

7.10.1

General

The RD316 Communications Interface module is specifically designed to provide
protocol conversion and direct connection between the MAXPRO-Net system and third
party peripheral equipment. The RD316 allows for simplex, two wire half-duplex, and four
wire full duplex communication formats. Manchester, NRZ and NRZI encoding formats
are also supported. A switch-selectable transformer on board provides ground isolation
in these modes, if required.
7.10.2

Installation

The RD316 may be installed in any I/O slot within MAXPRO-Net subrack. All external
connections are via the subracks' DB25 connector for the appropriate slot. The following
table lists the connector pin-out details.
Rev. C
DB25 pin
Description
3
Ground
4
Ground
5
RX 'B'
6
RX 'B'
7
TX 'B'
8
TX 'B'
9
Transformer 'B'
10
Transformer 'B'
11
Transformer 'B'
12
Transformer 'B'
16
Ground
17
Ground
18
RX 'A'
19
RX 'A'
20
TX 'A'
21
TX 'A'
22
Transformer 'A'
23
Transformer 'A'
24
Transformer 'A'
25
Transformer 'A'
WARNING: Honeywell makes no representation and
offers no warranties as to the accuracy and/or suitability
of third party protocols and command formats. Such
protocols and command formats are based upon
information supplied to Honeywell by third party
manufacturers/suppliers at the time of implementation.